Supplying batteries since 1952

PMM BATTERY FEATURE SEPTEMBER ‘13

Written on July 21, 2013 at 5:18 pm

Manbat

Overview

For many years the battery market remained relatively static when it came to the technology that was incorporated into the typical car battery. While the major manufacturers obviously invested in improving the performance of their batteries, they were all generally lead-acid batteries designed to cater for large current discharge when starting the engine and subject to continuous charging while the vehicle was in use.

As far as the workshop was concerned, providing the battery was maintained properly – topped up with de-ionised water, kept from excessive discharge and regularly charged etc. – it would provide a reliable source of power until it inevitably needed to be replaced. Replacement was a simple and straightforward process, which was only complicated by the fact that in more recent years a current had to be maintained in the system to ensure the power to the ECU and related equipment wasn’t lost.

However, the introduction of Start-Stop vehicles has driven a major change in battery technology. Start-Stop, otherwise known as micro hybrid, engines have become the preferred route for most of the vehicle manufacturers in order for them to reduce the fuel consumption of their vehicles and achieve the European Union requirement for fleet average vehicle emissions.

The traditional lead-acid ‘starter’ battery is not suitable for this type of engine and therefore cannot be used. Instead it requires a battery that can deliver the starting power of a traditional automotive battery with the cyclic (charge, discharge, charge etc.) capacity of a specialist mobility battery. The result is the absorbent glass mat (AGM) battery, which was first developed by VARTA® for whom Manbat is the UK’s largest supply partner.

Question
What challenges do technicians face when changing AGM batteries compared to lead-acid based batteries?

Answer
With a Start-Stop vehicle fitted with an AGM battery, the technician cannot just replace the battery in the way that they have done with a traditional battery where, as mentioned earlier, the greatest challenge was simply to ensure a supply feed was maintained.

Instead as the battery is intricately linked to the vehicle’s on-board electronics via a battery management system (BMS) or intelligent battery sensor (IBS), so it has to be integrated into the system and paired with the BMS/IBS, which requires specialist equipment. Without the equipment to assist the technician and introduce the battery into the system, the vehicle could illuminate error messages on the dash, fail to charge the battery or simply not start at all.

Question
Is dedicated training as to how to test, diagnose and fit these new batteries a requirement?

Answer
Training is particularly important because the number of potential faults in a Start-Stop system is far greater than for a traditional electrical system. Because the engine is switched off as frequently as possible and only restarts when the vehicle needs to move off or when the state of charge of the battery drops to a predetermined level, the BMS is extremely complicated. Therefore the correct testing procedure and fault diagnosis is vital. This is also complicated by the fitting challenges mentioned previously.

Question
Will any AGM battery do the job?

Answer
As with every aspect of the trade, fitting the correct battery for the application is paramount. For entry-level or smaller Start-Stop vehicles for example, an AGM battery might not be the appropriate replacement as the original fitment could be an enhanced flooded battery (EFB). Although these batteries have similar characteristics to AGM batteries, they are not the same and the two should not be interchanged. Likewise, just installing a larger capacity lead-acid battery is no solution for Start-Stop battery replacement.

To prevent error messages and other installation related problems, quality Start-Stop batteries should be the first thought when being replaced, as these will have the necessary 2D codes to ensure the battery is a ‘match’ for the vehicle and be ‘accepted’ by the BMS/ECU.

Question
Are there any specific procedures for the removal, fitting or disposal of AGM batteries?

Answer
Technicians working on Start-Stop vehicles will find that is no guarantee that the battery will be under the bonnet! Therefore, they need to have access to accurate technical information such as TecRMI, or similar workshop related technical data, to pinpoint the exact location of the battery, be it in the boot floor or, as it is in at least one application, beneath the front passenger seat!

Handling AGM batteries themselves is no more hazardous than their traditional lead acid cousins, in fact as they are general completely sealed units, chemical spillage is actually less likely. However, they are heavy, so health and safety procedures should obviously be followed carefully.

When it comes to responsible disposal, workshops have to understand their environmental responsibilities and ensure batteries are disposed of legally, but they should also be aware that they could benefit finically from responsible battery disposal as batteries have a ‘scrap’ value.

Manbat is a member of the ECOBAT group, which includes specialist waste battery businesses and lead smelter ECOBAT Technologies, one of the world’s leading suppliers of lead. Annually ECOBAT converts millions of tons of lead waste into high quality lead ingots, strip, wire and shot through its efficient smelters across the globe. Among its many customers are a number of major battery manufacturers and some of these brands are subsequently distributed nationally through Manbat’s comprehensive branch network.

The combination of new battery sales and distribution, together with waste battery collection, recycling and the reintroduction of lead into the manufacturing process, means that the ECOBAT group, and therefore Manbat, is able to be exceptionally environmentally aware and is currently the only global company offering a closed recycling loop for lead-acid batteries.

Question
Are there any specific maintenance requirements?

Answer
Providing the vehicle’s BMS is working as it is intended, these batteries require no specific maintenance. They are fully sealed and maintenance free.

Question
Will garages need to upgrade their equipment top work on Start-Stop vehicles?

Answer
Without the correct equipment workshops cannot test the battery and the associated elements in the Start-Stop system. This equipment allows them to diagnose whether a fault lies with the battery, alternator, BMS, IBS or elsewhere.

Question
What advices should garages give their customers when their battery needs replacing?

Answer
Workshops should choose a quality battery when undertaking replacement, but this is even more important when working on Start-Stop vehicles for the reasons previously discussed. VARTA is the largest original equipment battery supplier to Europe’s vehicle manufacturers and has led the development of Start-Stop battery technology. As a result, by fitting VARTA a like for like replacement is highly likely, but whatever the original battery, the necessary quality is guaranteed.

For non Start-Stop applications Manbat recommends the use of an application guide like its just-launched Lucas Battery Catalogue, to ensure the correct specification battery is selected.

Only when the vehicle has been fitted with additional electrical equipment or when the vehicle has been modified to cope with extreme conditions, does the battery need to be upgraded. In this instance the enhanced performance of an AGM battery could be an advantage even though the vehicle doesn’t utilise a Start-Stop system.

Go Back